Falla

Soldadora conectada por error a 380V

Wrong-voltage damage path: entrada fuse, varistor, rectificador, capacitores y fuente auxiliar.

Damage pattern

When a soldadora is connected to the wrong high tensión de entrada, the damage usually starts at the entrada protección y energy-storage path. The falla can then spread into the auxiliary supply y placa de control. A máquina that only blows the fuse may still have hidden rectificador, capacitor o varistor damage.

Inspection sequence

Disconnect y discharge
Inspect fuse / breaker
Inspect MOV / NTC / entrada traces
Test puente rectificador
Inspect bulk capacitores
Comprobación auxiliary PWM supply
Comprobación placa de rieles de control
Potencia up con current limiting

Common damaged parts

Do not simply replace the fuse

Replacing the fuse without comprobacióning the entrada puente, capacitores y fuente auxiliar etapa can cause a second failure y may destroy more expensive parts.