Power circuit reference
ZX7-500A 3-Phase 380V Power Path
Use this page to move from input power evidence to IGBT switching and output rectifier evidence on ZX7-500A 3-phase machines.
High-energy path
The high-energy path is not a single replaceable board. Treat input rectification, DC bus storage, IGBT inverter, main transformer, output diode modules and output reactor as separate evidence layers.
Power-path evidence table
| Section | Normal evidence | Fault clue |
|---|---|---|
| Input / rectifier board | 3-phase AC becomes DC bus voltage | Breaker trip, missing bus, bridge short. |
| DC bus capacitors | stable DC link after rectifier | ripple, bulge, trip, slow discharge or bus imbalance. |
| IGBT inverter | gate-drive permission and switching | shorted IGBT, gate imbalance, snubber stress. |
| Output rectifier | rectified secondary output | no OCV, weak current, shorted 20040 module. |
| Filter reactor | smooth loaded welding current | unstable current, harsh arc, weak loaded response. |