Fault route

LGK100L Power-On No Response Diagnostic

A first-layer input and power-switch route for LGK100L machines that show no response at power-on.

Quick Answer

For LGK100L power-on no response, start with input power and power switch evidence. The source workflow treats incorrect input voltage at the switch and failed switch output as the first split.

Use this page when

  • Machine shows no response after power-on.
  • Input cable and power switch can be tested safely by a qualified technician.
  • You need to separate external power and switch failure from internal board failure.

Do not use this page when

  • The fan runs but display is off.
  • The machine trips breaker immediately.
  • Protection light turns on after the machine powers up.
Diagnostic Panel

LGK100L power-on no-response route

Input supply and switch output before board diagnosis.

Input power

Confirm the incoming three-phase supply reaches the power switch input.

Power switch input

If voltage on the switch input is wrong, trace cable and external supply.

Power switch output

If input is correct but output is wrong, suspect switch contacts or wiring.

Next control layer

Only after switch output is valid should downstream control power be diagnosed.

Power-on evidence table

Evidence pointExpected / abnormal evidenceRepair direction
Power-switch inputInput voltage is missing or incorrect.Check input cord, upstream supply and switch wiring.
Power-switch outputSwitch input normal but output abnormal.Repair wiring or replace switch.
Downstream boardsOnly relevant after valid switch output exists.Move to filter board/control transformer checks.

Next diagnostic step