MIG200DL Fan Not Running But Display Normal Diagnostic

A fan-branch route for MIG200DL welders where display works but the cooling fan does not run.

Quick Answer

For MIG200DL fan not running while display is normal, split the bottom-board AC380V control-transformer supply, AC220V fan output and the fan itself.

Use this page when

  • Display is normal but fan does not rotate.
  • CON5/CON6 fan and transformer supply paths can be checked.
  • You need to separate bottom board output from fan failure.

Do not use this page when

  • Display is also off.
  • Fan runs but no output.
  • Breaker trips immediately.
Diagnostic Panel

MIG200DL fan-not-running / display-normal route

Separate fan output supply from the fan motor.

Display normal

Confirms auxiliary/display section is alive.

CON6 AC380V

Bottom board should output AC380V to control transformer supply path.

CON5 AC220V

Bottom board should output AC220V to the cooling fan.

Fan

If AC220V is present at fan path, inspect or replace fan.

Fan-not-running evidence table

Evidence pointExpected / abnormal evidenceRepair direction
Display statusDisplay normal while fan does not run.Use fan branch route.
CON6Bottom board should output AC380V for control transformer supply.If missing, inspect bottom board supply path.
CON5Bottom board should output AC220V for fan.If missing, inspect bottom board fan output.
Fan motorFan supply present but fan does not run.Replace fan or repair fan wiring.

Next diagnostic step