Fault route

WSE AC Output Missing but DC Output Normal Diagnostic

A secondary-stage diagnostic route for WSE AC/DC TIG machines.

Quick Answer

If WSE DC output is normal but AC output is missing, the primary inverter is probably not the first suspect. Check AC/DC panel command, secondary driver supply and secondary inverter switching.

Service map

WSE AC output missing route

Primary output first, then secondary command and switching.

DC output normal

Primary inverter/output path is working.

AC/DC command

Panel/control board should request AC mode.

Secondary driver

Driver supply/drive must reach secondary inverter.

Secondary inverter

Polarity switching stage creates AC output.

Balance/waveform

Check AC balance and output behavior.

AC-missing evidence table

EvidenceMeaningDirection
DC output normalPrimary stage not first suspect.Move to secondary stage.
AC mode command absentPanel/control-board command issue.Check WSE panel and command path.
Secondary driver absentSecondary driver/supply issue.Repair driver before inverter devices.
Secondary inverter not switchingSecondary power-stage issue.Check secondary switching devices and gate drive.
Balance abnormalCommand or switching mismatch.Check panel balance and secondary response.
Related records

Related records