Fault route

ZX7-160/200 Breaker Trip MOSFET Short Diagnostic

A small-inverter power-device route for ZX7-160/200 breaker trip or MOSFET short faults.

Quick Answer

Shorted MOSFETs can be the result, not the root cause. Separate DC bus short, top-board power devices, driver transformer and middle-board output load before installing replacement devices.

Diagnostic path

DC bus short → MOSFETs → driver transformer → middle-board load → replacement precheck.

Evidence table

Bus short: bridge/capacitor fault. MOSFET short: top inverter failure. Bad driver transformer: repeat device failure risk. Output diode/transformer load fault can stress inverter.