Model family · ZX7 / WS

ZX7 / WS stick-TIG inverter board family

This family page organizes ZX7, WS and related inverter stick/TIG machines by board role instead of only by model name. Use it to decide whether a no-output, protection, HF, gas or current-control fault belongs to the power board, long-strip control board, driver board or HF/gas section.

Board-stack view

Base / power board

Input rectifier, DC bus, auxiliary supply, relays, fan supply and power-stage mounting.

Upper / output board

Main transformer connection, output rectifier, filter capacitors, gate resistors and current feedback.

Long-strip control board

Current command, thrust adjustment, feedback, protection lamp, thermal input, 24V and drive connector.

Driver board

Translates PWM/control signal into isolated gate-drive signals for IGBT/MOSFET stage.

HF / TIG board

High-frequency arc-start, gas valve, hand-switch and TIG-specific start sequence on WS-type machines.

Panel board

Potentiometers, switches, meters, pulse controls or remote/foot-pedal interface.

Start from the symptom

SymptomStart hereThen check
Protection light on / no outputPower-stage shorts and thermal/protection inputFeedback line, long-strip board, drive connector.
No output, no protection lightDrive enable and driver boardPWM controller, auxiliary rails, gate-drive transformer.
Current cannot adjustCurrent pot and maximum-current trimFeedback signal and control-loop op-amp path.
TIG gas but no HFHF board and gas/HF relay sequenceHand switch, 24V, HF transformer, discharge path.
Weak outputOutput diode and feedback loopCurrent calibration, driver imbalance, DC bus under load.