Circuit reference

LGK Plasma Cutter Control Power Rails

A practical low-voltage rail reference connecting LGK60L and LGK100L fan, protection, display, feedback and no-output faults.

Quick Answer

LGK plasma-cutter control-power diagnosis should separate AC control-transformer rails from DC24V board outputs and sensor feedback supplies. This reference connects LGK60L and LGK100L evidence points.

Use this page when

  • You are diagnosing fan, display, protection, feedback or no-output faults in LGK plasma cutters.
  • The machine can be measured safely by a qualified technician.
  • You need to compare AC rails, DC outputs and feedback supplies.

Do not use this page when

  • The input breaker trips immediately before low-voltage checks.
  • The power stage is visibly shorted.
  • You only need torch consumable advice.
Service map

LGK control-power rail map

Low-voltage evidence used before replacing boards.

AC15V-0V-15V

LGK60L X17 and related control-transformer secondary evidence.

DC24V output

Fan and control output evidence such as LGK60L X16.

0-27V-36V group

LGK100L connector rail evidence used in protection/no-output workflows.

DC15V / -DC15V

Hall current-sensor supply evidence for feedback diagnosis.

DC5V display supply

Display/meter supply layer on larger platforms.

Control-power rail evidence

Rail / connector evidenceFault it can explainNext direction
LGK60L X17 AC15V-0V-15VFan/control abnormal; main board appears deadCheck control transformer and wiring.
LGK60L X16 DC24VFan not runningIf missing with fan disconnected, suspect main control board output.
LGK100L 0-27V-36V / 15V-0-15V groupProtection light or no outputCheck control transformer before replacing control board.
LGK100L X14 DC15V / -DC15VHall sensor/protection/no-output faultsCheck Hall sensor and feedback wiring.
DC5V meter/display supplyDisplay missing with fan runningSeparate display head from control board/power board.