Fault route

LGK100L No Output Diagnostic

A two-layer diagnostic route for LGK100L no-output faults, separating control/feedback evidence from power-stage evidence.

Quick Answer

LGK100L no-output diagnosis should be split into an upper control/feedback route and a lower power-output route. Do not replace the IGBT or driver board before confirming control transformer, potentiometer, Hall feedback, fast-recovery diode and filter capacitor evidence.

Use this page when

  • Machine powers up but has no cutting output.
  • Fan/display/control symptoms exist and output path can be measured.
  • You need to decide between control-board, feedback and power-stage faults.

Do not use this page when

  • Input breaker trips at power-on.
  • The machine is completely dead.
  • The only symptom is unstable current under load.
Diagnostic Panel

LGK100L no-output route

Two-layer route: control evidence first, output power evidence second.

1Control transformer

Check the control transformer output groups before blaming the output stage.

2Potentiometer

Open or bad current potentiometer can block expected command behavior.

3Hall feedback

Check DC15V, -DC15V and signal evidence on the Hall sensor connector.

4Fast-recovery diode

Disconnect and check diode characteristics if control evidence is not the cause.

5Filter capacitor

Burned or failed filter capacitors can remove output capability.

6IGBT / driver

Use driver-board indicator and visible burn evidence before replacement.

Measurement / evidence table

Evidence pointExpected / abnormal evidenceRepair direction
Control-board supply railsReference rail groups include 0-27V-36V and 15V-0-15V at the relevant connector.If missing, inspect control transformer and wiring.
Current potentiometerOpen potentiometer or bad contact blocks current command.Replace potentiometer after confirming wiring.
Hall sensor connectorBlack-red DC15V, black-blue -DC15V and signal-line behavior are used as source evidence.If abnormal, inspect Hall sensor and feedback path.
Fast-recovery diodeDiode-mode behavior should be checked after disconnecting related leads.Replace failed diode/module.
Filter capacitorBurned, bulged or failed filter capacitor can cause no output.Replace failed capacitor section.
IGBT and driver boardDriver green indicator and IGBT visual condition are used as evidence, not assumptions.Replace IGBT/driver only after upstream checks.

Next diagnostic step