Torch connector, electrode holder/tungsten clamp and work lead must be tight.
Fault route
LGK100L Weak Cutting Current Diagnostic
A current-too-small diagnostic route for LGK100L plasma cutters using external connection, command, feedback and shunt evidence.
Quick Answer
For LGK100L weak cutting current, split external output connection, current potentiometer, Hall sensor feedback, shunt/middle-board contact and main control board evidence.
- Loose torch/output/work connections can appear as weak current.
- A bad potentiometer or Hall sensor feedback path can make current command/feedback wrong.
- Poor shunt contact or middle-board issue should be considered before replacing the main control board.
Use this page when
- Cutting current is weak or welding/cutting current is small.
- Machine powers up and output exists but is insufficient.
- You need to decide between external output, potentiometer, Hall feedback, shunt and board faults.
Do not use this page when
- There is no output at all.
- Breaker trips at power-on.
- IGBT is visibly burned.
LGK100L weak-current route
External connection first, feedback and shunt evidence before board replacement.
Open or poor contact can limit current command.
Check DC15V, -DC15V and signal line behavior.
Poor shunt contact or middle-board fault can reduce current evidence.
Replace only after external, command and feedback evidence are checked.
Weak-current evidence table
| Evidence point | Expected / abnormal evidence | Repair direction |
|---|---|---|
| Output cable / torch connector | Loose connector or poor work return reduces real current. | Repair mechanical connection first. |
| Current potentiometer | Open or bad contact changes current command. | Replace potentiometer if unstable/open. |
| Hall sensor connector | Expected DC15V/-DC15V supply and signal behavior at X14-style feedback path. | Inspect/replace Hall sensor and wiring. |
| Shunt / middle board | Poor contact or middle-board fault affects current detection/current path. | Repair contact or replace middle board if proven. |
| Main control board | All external/feedback evidence normal but current remains weak. | Main control board becomes suspect. |