Diagnostic workflow

Rotary DC Arc Welder Common Fault Routing

Use this workflow for older motor-generator DC arc welders before treating weak output or no output as a generator failure.

Fault-routing map

Rotary DC arc welder fault routing map.
Route by motor behavior, generator output, field-control evidence, brush condition and output-cable loss.

Symptom routing table

SymptomFirst checksLikely section
Motor does not runInput supply, switch, fuse, starter/contact, motor winding and mechanical lock.Input / motor section.
Motor runs but there is no welding outputField continuity, field resistor, brush contact, open-circuit voltage at output terminals.Field excitation or generator output.
Weak weld currentCurrent-control rheostat, output cable, holder, work clamp, brush pressure and generator load response.Field control or output circuit.
Current cannot be adjustedRange switch, rheostat, field-control path and mechanical linkage.Current-control section.
Arc is unstableBrush sparking, commutator contamination, cable connection, electrode holder and work return.Brush/commutator or external output path.
Brushes spark heavilyBrush wear, spring force, holder position, commutator surface and overload condition.Brush / commutator maintenance fault.
Machine overheatsCooling fan, ventilation, bearing friction, overload duty and field/armature temperature.Mechanical cooling or electrical overload.

Stop conditions

Repair record template

Record fieldExample evidence to write down
Motor stateStarts / does not start, reaches speed, noise, vibration, fan.
OCVMeasured open-circuit voltage at output terminals.
Field pathField continuity, rheostat position, range switch condition.
Brush/commutatorBrush length, spring pressure, sparking, carbon dust, commutator surface.
Output pathWelding cable, holder, clamp, work return and heat marks.