Quick Answer

A protection light can be caused by real overheating, output short, MOSFET short, feedback abnormality or false protection input. Do not replace the control board before checking thermal switch, output path and power-device short evidence.

Diagnostic path

Thermal switch → output short → MOSFET/driver short → shunt/feedback path → control-board protection input.

Evidence table

Protection after power-on: check power-device/output short. Protection after load: check thermal path and output stage. Fan running but protection locked: feedback or protection input may be stuck.