Digital NBC-III fault evidence

Symptom / codeLikely evidence layerRepair direction
Current cannot adjustfeeder cable, controller, current sensor, control boardVerify cable/controller before condemning main control board.
Wire stubbing at arc startslow wire-feed value too highUse slow-feed menu and set a lower approach speed.
Large ball at wire endburn-back time too longReduce burn-back time; verify crater-fill/stop sequence.
Display 803wire short protectionA wire/work short held too long stops the machine; restart after clearing short.
Display 804thermal protectionCheck fan behavior, duty cycle and thermal relay wiring.
Display 805voltage-feedback protectionInspect voltage feedback path, return lead and control wiring.