Model reference

WIG160 AC/DC Inverter TIG Welder Reference

A WelderData reference for compact MOSFET AC/DC inverter TIG welders, focused on routing faults between inverter power stage, AC/DC selection, HF start, gas timing and protection rails.

Database summary

WIG160-style AC/DC inverter TIG welders use a compact inverter power stage and additional AC/DC output-control logic. They can show mixed faults: DC stick or DC TIG may work while AC TIG fails, or HF and gas may work while the AC output does not switch correctly.

WelderData treats this platform as a compact inverter TIG family rather than a generic TIG symptom page. The repair path begins with safe power checks, auxiliary rails, HF/gas evidence and then mode-specific output response.

Mode-based diagnosis

Observed behaviorLikely routeDo not confuse with
Stick output works but TIG does notTorch/HF/gas/TIG enable pathMain inverter short failure
DC TIG works but AC TIG failsAC/DC switching or polarity-control pathGas or HF-only fault
HF spark exists but arc does not stabilizeArc transfer, output enable or feedback pathHF transformer only
Machine shuts down under AC loadProtection, feedback or output switching stressPanel display fault only

Related pages